CAD (0)
▾
HydroFlame Pro Firestop Sleeve with Adjustable Cap
Through-Penetration Firestop Sleeves
- Ideal for flat concrete form decks – cast-in-place
- Ideal for corrugated metal decks (corrugated deck plate required)
- Available for 1/2” to 6” penetrants, piping, conduits, cables, etc.
- For insulated and non-insulated pipes
- 7-1/4” – 8” Tall with adjustable cap and can be cut to as short as 3-1/2”. Extensions available
- Black base and black whiskers identifies metal piping system
- Red base and red whiskers identifies plastic or metal piping system
- Includes locator whiskers, to locate buried sleeves and to identify pipe type (metal or plastic)
- Dimensions on sleeve allows for simple height adjustment when cutting
- Safety caps meet OSHA hole cover requirements
- UL Listed firestop devices (2 or 3 hour F-ratings)
- Meets and/or exceeds building code requirements
- Built in fire, smoke, gas and water protection
- UL W-Rated seal, water-tight for most penetrants
- Allows for contraction, expansion, movement and off-center pipes
- Reduces piping system noise transfer by maintaining annular spacing
- Interlocking base capability assists with layout alignment
- A variety of accessories are available
- UL 50 Pa Ratings
Item # |
Penetrating Pipe Type |
Nominal Penetrant Size |
Box Qty |
Revit |
---|---|---|---|---|
HFP-P1B | Penetrating Pipe Type N/A Plastic and Metal | Nominal Penetrant Size N/A 1/2 - 1 | Box Qty N/A 10 | Revit N/A |
HFP-P2B | Penetrating Pipe Type N/A Plastic and Metal | Nominal Penetrant Size N/A 1-1/4 - 2 | Box Qty N/A 10 | Revit N/A |
HFP-P3B | Penetrating Pipe Type N/A Plastic and Metal | Nominal Penetrant Size N/A 2 - 3 | Box Qty N/A 10 | Revit N/A |
HFP-P4B | Penetrating Pipe Type N/A Plastic and Metal | Nominal Penetrant Size N/A 3 - 4 | Box Qty N/A 10 | Revit N/A |
HFP-P5B | Penetrating Pipe Type N/A Plastic and Metal | Nominal Penetrant Size N/A 4 - 5 | Box Qty N/A | Revit N/A |
HFP-P6B | Penetrating Pipe Type N/A Plastic and Metal | Nominal Penetrant Size N/A 5 - 6 | Box Qty N/A 2 | Revit N/A |
HFP-M1B | Penetrating Pipe Type N/A Metal | Nominal Penetrant Size N/A 1/2 - 1 | Box Qty N/A 10 | Revit N/A |
HFP-M2B | Penetrating Pipe Type N/A Metal | Nominal Penetrant Size N/A 1-1/4 - 2 | Box Qty N/A 10 | Revit N/A |
HFP-M3B | Penetrating Pipe Type N/A Metal | Nominal Penetrant Size N/A 2 - 3 | Box Qty N/A 10 | Revit N/A |
HFP-M4B | Penetrating Pipe Type N/A Metal | Nominal Penetrant Size N/A 3 - 4 | Box Qty N/A 10 | Revit N/A |
HFP-M5B | Penetrating Pipe Type N/A Metal | Nominal Penetrant Size N/A 4 - 5 | Box Qty N/A | Revit N/A |
HFP-M6B | Penetrating Pipe Type N/A Metal | Nominal Penetrant Size N/A 5 - 6 | Box Qty N/A 2 | Revit N/A |