Type |
N/A Thermostatic Mixing Valve Kit |
Connection Type |
N/A 3/4" MNPT Mix Outlet x 3/4" FNPT Union Fitting x 3/4" NPSH Cold Inlet |
Size |
N/A 3/4" |
Operating Temperature [Min] |
N/A 32 ºC90 ºF |
Operating Temperature [Max] |
N/A 55 ºC130 ºF |
Operating Pressure [Max] |
N/A 150 psi |
Flow Rate Minimum |
N/A 1 gpm (4L/min) |
Flow Rate Maximum |
N/A See flow curve |
Factory Set Temperature Range |
N/A 115 - 120 ºF (46 - 48.9 ºC) |
Hot Temperature Supply Range |
N/A 120 - 180 ºF (48.9 - 82.2 ºC) |
Cold Temperature Supply Range |
N/A 39 - 80 ºF (5 - 27 ºC) |
Body Material |
N/A DZR brass |
Seals Material |
N/A EPDM |
Springs Material |
N/A Stainless Steel |
Internal Cap Material |
N/A Brass |
Piston Material |
N/A Engineered Polymer |
Features and Benefits |
N/A Precise temperature control: Safer hot water from all outlets. Allows the water heater to be set at 140°F (60°C) or higher: Greater effective hot water volume and less chance of Legionella within the cylinder Every valve is tested for performance prior to shipping: Specify and install with confidence! More hot water from the same water heater: Higher storage temperature means a greater effective hot water volume delivered at a safe 120°F (49°C). Robust, low complexity construction: Superior reliability, improved user safety. Adjustable and lockable mechanism: Minimizes unauthorized tampering with valve setting. Factory set at 120°F (49°C) Listed by IAPMO and ASSE: Inspector friendly, peace of mind. Integral recirculation port Allows quick and neat installations in systems with recirculation. |
Specification |
N/A A Temperature Actuated Mixing Valve shall be installed at the water heater to distribute tempered water throughout the domestic hot water system at a temperature of 120°F (49°C). The valve shall be certified to ASSE 1017, CSA B 125.3, NSF 372, NSF 61 and shall be listed by a third party. The Temperature Actuated Mixing Valve shall control the delivered water temperature via a regulating piston made from engineered polymer. The adjusting mechanism shall be lockable. The valve shall be a Cash Acme Tank Booster Pro. |
Typical Installation |
N/A Residential and commercial hot water distribution applications. To control water temperature at the source of heat (water heater) to provide a safe distribution temperature. |
Certifications |
N/A The Cash Acme Tank Booster is certified to ASSE 1017, ASSE 1070, CSA B125.3, NSF/ANSI 61, and NSF 372 and listed by IAPMO and ASSE for use in accordance with the U.S. and Canadian plumbing codes. |