    The HOLDRITE® #117 Series is the ideal solution for restraining hubless cast iron soil pipes against separation during high thrust conditions. HOLDRITE #117 Series installs in minutes without on-site cutting, bending, measuring, or modifications needed while providing the ideal professional solution for no-hub DWV joints in potential thrust force situations.

    This No-Hub Fitting Restraint is made to prevent separation of no-hub pipe fittings at changes of direction or straight in-line joints. These engineered restraints protect against water blow-outs in rain leader systems, plus support joints from the separation of both longitudinal movements and diagonal misalignment.

    • Ideal for restraining hubless cast iron soil pipe against separation during high thrust conditions
    • Engineered to meet plumbing codes, pipe manufacturers’ installation instructions, and CISPI installation handbook
    • Installs in minutes
    • Built with stainless steel, black iron and/or galvanized components
    • No special tools required for installation
    • No field cutting or modifications required
    • All components included in each kit

  • Holdrite-117-LS-Series-Galvanized-Steel

    The HOLDRITE® #117-LS Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations at 90° (long sweep) changes of direction, in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18 and the 2006 CISPI Installation Handbook. The #117-LS (2" – 6” in size) retain the 90° elbow onto the adjoining piping using stainless steel bands which must be torqued to 60 in/lbs minimum. When installed correctly, these restraint brackets achieve a safe thrust pressure rating equal to 50' head of water pressure.

  • Holdrite-117-LL-Series-Galvanized-Steel

    The HOLDRITE® #117-LL Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18, and the 2006 CISPI Installation Handbook. The #117-LL (2" - 8" size) retains two 45° 1/8 bends onto the adjoining piping. All stainless steel bands must be torqued to 60 in/lbs minimum. When installed correctly, these restraint brackets achieve a safe thrust pressure rating equal to 50' head of water pressure.

  • Holdrite-117-L-Series-Black-Iron

    The HOLDRITE® #117 Series is the ideal solution for restraining hubless cast iron soil pipes against separation during high thrust conditions. HOLDRITE #117 Series installs in minutes without on-site cutting, bending, measuring, or modifications needed while providing the ideal professional solution for no-hub DWV joints in potential thrust force situations.

    This No-Hub Fitting Restraint is made to prevent separation of no-hub pipe fittings at changes of direction or straight in-line joints. These engineered restraints protect against water blow-outs in rain leader systems, plus support joints from the separation of both longitudinal movements and diagonal misalignment.

    • Ideal for restraining hubless cast iron soil pipe against separation during high thrust conditions
    • Engineered to meet plumbing codes, pipe manufacturers’ installation instructions, and CISPI installation handbook
    • Installs in minutes
    • Built with stainless steel, black iron and/or galvanized components
    • No special tools required for installation
    • No field cutting or modifications required
    • All components included in each kit

  • Holdrite-117-S-Series-Galvanized-Steel

    The HOLDRITE® #117-S Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations of Straight Couplings, in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18, and the 2006 CISPI Installation Handbook. The #117-S (2" – 8” in size) retain the adjoining piping sections using stainless steel bands which must be torqued to 60 in/lbs minimum. When installed correctly, these restraint brackets achieve a safe thrust pressure rating equal to 50' head of water pressure. For sizes 10”-15”, heavy duty steel pipes clamp and straps are used and require 60 ft/lbs of torque on pipe clamp bolts

  • Holdrite-117-BP-Series-Galvanized-Steel

    The HOLDRITE® #117-BP Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations of Blind Plugs/Caps, in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18, and the 2006 CISPI Installation Handbook. The #117-BP (2" – 8” in size) retain the plugs onto the adjoining piping using stainless steel bands which must be torqued to 60 in/lbs minimum. When installed correctly, these restraint brackets achieve a safe thrust pressure rating equal to 50' head of water pressure. For sizes 10”-15”, a heavy duty steel pipe clamp and straps are used and require 60 ft/lbs of torque on pipe clamp bolts

  • Holdrite-117-W-Series-Galvanized-Steel

    The HOLDRITE® #117-W Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18, and the 2006 CISPI Installation Handbook. The #117-W (2” – 8”) retains the Wye fitting onto the adjoining piping, in mid-span runs. All stainless steel bands must be tightened to 60 in/lbs minimum. When installed correctly, these restraint brackets achieve a safe thrust pressure rating equal to 50' head of water pressure. For sizes 10”-15”, heavy duty steel pipe clamps and straps are used and require 60 ft/lbs of torque on pipe clamp bolts

  • Holdrite-117-WR-Series-Galvanized-Steel

    The HOLDRITE® #117-WR Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18, and the 2006 CISPI Installation Handbook. The #117-WR (12”x 4” – 15”x 12”) retains the Wye fitting onto the adjoining piping, in mid-span runs.. For these 12”-15” products, heavy duty steel pipe clamps and straps are used and require 60 ft/lbs of torque on pipe clamp bolts

  • Holdrite-117-WR-Series-Galvanized-Steel

    The HOLDRITE® #117-WR Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18, and the 2006 CISPI Installation Handbook. The #117-WR (12”x 4” – 15”x 12”) retains the Wye fitting onto the adjoining piping, in mid-span runs.. For these 12”-15” products, heavy duty steel pipe clamps and straps are used and require 60 ft/lbs of torque on pipe clamp bolts

  • Holdrite-117-CM-Series-Galvanized-Steel

    The HOLDRITE® #117-CM Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18, and the 2006 CISPI Installation Handbook. The #117-3CM through #117-8X6CM retains the Combo or Wye with 1/8 bend onto the adjoining piping. All stainless steel bands must be tightened to 60 in/lbs minimum. When installed correctly, these restraint brackets achieve a safe thrust pressure rating equal to 50' head of water pressure.

  • Holdrite-117-CE-Series-Galvanized-Steel

    The HOLDRITE® #117-CE Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18, and the 2006 CISPI Installation Handbook. The #117-3CE thru #117-8X6CE retains the Combo or Wye fitting onto the adjoining piping when positioned at the end of the line and when either a blind plug or a cleanout is installed. All stainless steel bands must be torqued to 60 in/lbs minimum. When installed correctly, these restraint brackets achieve a safe thrust pressure rating equal to 50' head of water pressure.

  • Holdrite-117-R-Series-Galvanized-Steel

    The HOLDRITE® #117 Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers and the 2006 CISPI Installation Handbook. The #117-3R Series Restraints are for 2" -8 " fitting reducers and retain the fittings between the adjoining piping. All four stainless steel bands must be tightened to 60 in/lbs minimum.

  • Holdrite-117-T-Series-Galvanized-Steel

    The HOLDRITE® #117-T Series No-Hub Fitting Restraints are designed to reinforce no-hub cast iron installations of Test/Cleanout Tees, in accordance with the installation instructions of U.S. cast iron soil pipe manufacturers, CISPI Designation 301-18, 310-18, and the 2006 CISPI Installation Handbook. The #117-T (2" – 8” in size) retain the reducer fittings onto the adjoining piping using stainless steel bands which must be torqued to 60 in/lbs minimum. When installed correctly, these restraint brackets achieve a safe thrust pressure rating equal to 50' head of water pressure. For the 10” size, heavy duty steel pipes clamp and straps are used and require 60 ft/lbs of torque on pipe clamp bolts